CDC logoSafer Healthier People  CDC HomeCDC SearchCDC Health Topics A-Z
NIOSH - National Institute for Occupational Safety and Health

Skip navigation links Search NIOSH  |  NIOSH Home  |  NIOSH Topics  |  Site Index  |  Databases and Information Resources  |  NIOSH Products  |  Contact Us

Search for NIOSH Publications: NIOSHTIC-2

NIOSHTIC-2 Search Results

      Advanced Search  |  Help  |  About  |  Feedback 
Terms: 20035162 1 - 1 of 1 Bibliographic entries All record(s) shown.
Save All   |   Save Page View Saved    |    Download
Select check boxes to automatically save entries, or use 'save all' or 'save page' links above.

 1 A revised conversion factor relating respirable dust concentrations measured by 10 mm Dorr-Oliver nylon cyclones operated at 1.7 and 2.0 L min(-1)
Authors Page-SJ; Volkwein-JC 
Source J Environ Monit 2009 Mar; 11(3):684-689 
Link http://dx.doi.org/10.1039/b817922k 
NIOSHTIC No. 20035162 
AbstractAccurate measurement of workplace respirable dust concentration is an essential step in eliminating lung disease in any occupational setting. In the United States (U. S.) coal mining industry, this measurement process has relied upon a personal sampler that includes a 10 mm Dorr-Oliver (DO) nylon cyclone operated at a flow rate of 2.0 L min(-1) to collect a respirable dust sample. Dust concentrations measured with this sampler are multiplied by 1.38, which was empirically derived, to convert them to measurements approximating the United Kingdom British Medical Research Council (BMRC) definition of respirable dust upon which the health effects of coal mine dust are based. The International Organization for Standardization (ISO) subsequently refined the respirable dust definition and the U. S. National Institute for Occupational Safety and Health (NIOSH) 1995 Criteria for a Recommended Standard presented a conversion multiplier of 0.857 to apply to the 2.0 L min(-1) DO (in addition to the 1.38 multiplier) to obtain equivalent ISO concentrations, as approximated by the 1.7 L min(-1) DO. However, the conversion multiplier 0.857 was derived indirectly from a limited size distribution data set rather than a direct comparison of the DO samplers. The present analysis focuses on providing a more accurate conversion multiplier derived from direct comparisons of the 2.0 L min(-1) (with 1.38 BMRC equivalency multiplier) and 1.7 L min(-1) DO cyclones. A weighted linear regression analysis of this database suggests that a more accurate estimate of the conversion multiplier is 0.815. 
KeywordsAnalytical-Method; Aerosol-particles; Aerosol-sampling; Biological-effects; Biological-factors; Biological-function; Coal-dust; Coal-miners; Coal-mining; Dust-exposure; Dust-inhalation; Dust-particles; Dust-sampling; Lung-irritants; Mathematical-models; Particulates; Pulmonary-function; Pulmonary-system; Respiratory-hypersensitivity; Respiratory-irritants; Respiratory-system-disorders; Statistical-analysis; Author Keywords: Aerosol sampler 
Page 1 of 1
All record(s) shown.